Login
Toggle sidebar

Lint: aliasing-phenomenon-ultrasound

Units
error

"Aliasing occurs in colour Doppler when the speed of blood flow exceeds 0.4-0.7m/s 6."

Line 19:81 · Put a space between the number and the unit in '7m'.
Acronyms
warning

"The Nyquist limit defines the frequency at which aliasing and range ambiguity will occur, and is equal to the PRF/2. Factors such as higher velocities of target structures and increasing depth of the region of interest insonated will result in aliasing and consequent range ambiguity. Other potential causative factors include:"

Line 5:121 · 'PRF' has no definition. Spell it out if it's unfamiliar to the audience.

"A specific use for aliasing in echocardiography is the calculation of the effective regurgitation orifice area in the assessment of valvular regurgitation, most commonly involving the mitral valve. With colour Doppler interrogation of a mitral regurgitant jet, a hemispheric flow convergence forms surface area tapering to form the vena contracta before entering the left atrium. The hemispheric area (PISA) is calculated and the product of PISA and aliasing velocity yields regurgitant flow. The quotient with calculated MR regurgitant VTI yields EROA."

Line 14:406 · 'PISA' has no definition. Spell it out if it's unfamiliar to the audience.

"A specific use for aliasing in echocardiography is the calculation of the effective regurgitation orifice area in the assessment of valvular regurgitation, most commonly involving the mitral valve. With colour Doppler interrogation of a mitral regurgitant jet, a hemispheric flow convergence forms surface area tapering to form the vena contracta before entering the left atrium. The hemispheric area (PISA) is calculated and the product of PISA and aliasing velocity yields regurgitant flow. The quotient with calculated MR regurgitant VTI yields EROA."

Line 14:445 · 'PISA' has no definition. Spell it out if it's unfamiliar to the audience.

"A specific use for aliasing in echocardiography is the calculation of the effective regurgitation orifice area in the assessment of valvular regurgitation, most commonly involving the mitral valve. With colour Doppler interrogation of a mitral regurgitant jet, a hemispheric flow convergence forms surface area tapering to form the vena contracta before entering the left atrium. The hemispheric area (PISA) is calculated and the product of PISA and aliasing velocity yields regurgitant flow. The quotient with calculated MR regurgitant VTI yields EROA."

Line 14:552 · 'EROA' has no definition. Spell it out if it's unfamiliar to the audience.

"In case of spectral Doppler the velocity peak is cut off at the peak of the scale, and the peak is displayed at the bottom of the scale, often overlapping with the rest of the curve. The artifact can be quickly remedied by lowering the baseline (if display of flow away from the transducer is not required), or increasing the PRF."

Line 16:330 · 'PRF' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Case
warning

"Pulsed wave Doppler"

Line 15:5 · 'Pulsed wave Doppler' should use sentence-style capitalization.

"Colour flow Doppler"

Line 17:5 · 'Colour flow Doppler' should use sentence-style capitalization.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Physics"

Line 2:1 · "Physics" is not a recognised heading for this article type.

"Clinical use"

Line 11:1 · "Clinical use" is not a recognised heading for this article type.

"Ultrasound"

Line 12:1 · "Ultrasound" is under the wrong parent heading (found under "Clinical use").

"Echocardiography"

Line 13:1 · "Echocardiography" is not a recognised heading for this article type.

"Pulsed wave Doppler"

Line 15:1 · "Pulsed wave Doppler" is not a recognised heading for this article type.

"Colour flow Doppler"

Line 17:1 · "Colour flow Doppler" is not a recognised heading for this article type.
Semicolons
suggestion

"Pulsed wave Doppler and colour flow Doppler operate on this presumption; when a location of interest is designated, the ultrasound machine will only record returning echoes during an interval that corresponds to the time necessary for wave egress and return along a linear path. If Doppler shifts occur at a frequency exceeding the maximum pulse interval (1/pulse repetition frequency) detected phase shifts will be calculated based on incorrect assumptions."

Line 4:89 · Use semicolons judiciously.