Login
Toggle sidebar

Lint: cardiac-gating-ct

Units
error

"For higher heart rates (>80bpm), end-systolic acquisition (30-35% of R-R interval, or 350ms) 2 is often utilised because the slowest-motion phase shifts into systole at about >83 bpm 3."

Line 4:90 · Put a space between the number and the unit in '350ms'.
Headings Spacing
error

"Gated protocols in cardiac CT "

Line 5:1 · Never put spaces at either end of headings.
En Dash
error

"This mode requires a regular sinus rhythm and heart rate well below 6065 bpm; an auto-gating software can detect if these criteria are met and make suggestions regarding the optimal protocol 3."

Line 35:74 · Use a hyphen-minus ('-') instead of an en-dash ('–').
Words We Never Use
error

"Motion correction algorithms can improve image quality at both low and high heart rates, enhancing the diagnostic value of scan data affected by motion artefacts 3."

Line 38:156 · Radiopaedia always uses 'artifacts' rather than 'artefacts'.
Acronyms
warning

"Via the attachment of ECG leads, cardiac gating aims to find a consistent portion of the R-R interval (measured as a percentage), most commonly at the mid to end-diastolic phase (around 70% of the R-R interval) 1, where movement is at its least."

Line 3:93 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.

"Via the attachment of ECG leads, cardiac gating aims to find a consistent portion of the R-R interval (measured as a percentage), most commonly at the mid to end-diastolic phase (around 70% of the R-R interval) 1, where movement is at its least."

Line 3:201 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.

"For higher heart rates (>80bpm), end-systolic acquisition (30-35% of R-R interval, or 350ms) 2 is often utilised because the slowest-motion phase shifts into systole at about >83 bpm 3."

Line 4:73 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.

"Prospective protocols mean a predetermined portion of the R-R interval is selected for scanning. It is not a functional study; however, it is useful to reduce motion artifact."

Line 30:62 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.

"40% of R-R interval"

Line 49:19 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.

"60-70% of R-R interval"

Line 53:22 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.

"50-60% of R-R interval"

Line 57:22 · 'R-R' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Clinical applications
  • H2 Indications
  • H2 Contraindications
  • H1 Technique
  • H2 Physical principles
  • H2 Device structure
  • H2 Device function
  • H2 Image acquisition
  • H2 Image reconstruction
  • H2 Post-processing
  • H2 Technical advances
  • H2 Protocols
  • H1 Interpretation
  • H2 Normal values
  • H2 Limitations
  • H2 Pitfalls and artifacts
  • H1 History and etymology
  • H1 Practical points
  • H1 Related articles
  • H1 See also

"Gated protocols in cardiac CT "

Line 5:1 · "Gated protocols in cardiac CT " is not a recognised heading for this article type.

"Prospectively ECG-gated cCTA protocols"

Line 29:1 · "Prospectively ECG-gated cCTA protocols" is not a recognised heading for this article type.

"Prospective ECG gated (step and shoot)"

Line 31:1 · "Prospective ECG gated (step and shoot)" is not a recognised heading for this article type.

"High-pitch spiral acquisition"

Line 33:1 · "High-pitch spiral acquisition" is not a recognised heading for this article type.

"Limitations of prospectively ECG-gated protocols"

Line 36:1 · "Limitations of prospectively ECG-gated protocols" is not a recognised heading for this article type.

"Retrospectively ECG-gated cCTA protocols"

Line 39:1 · "Retrospectively ECG-gated cCTA protocols" is not a recognised heading for this article type.

"Specific artery selection"

Line 44:1 · "Specific artery selection" is not a recognised heading for this article type.
There Is
suggestion

"There are several different protocols based on the patient presentation that can be broken into prospective and retrospective:"

Line 6:4 · Don't start a sentence with 'There are'.
Semicolons
suggestion

"Prospective protocols mean a predetermined portion of the R-R interval is selected for scanning. It is not a functional study; however, it is useful to reduce motion artifact."

Line 30:129 · Use semicolons judiciously.

"This mode requires a regular sinus rhythm and heart rate well below 60–65 bpm; an auto-gating software can detect if these criteria are met and make suggestions regarding the optimal protocol 3."

Line 35:81 · Use semicolons judiciously.