Login
Toggle sidebar

Lint: dose-length-product

Acronyms
warning

"The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose."

Line 3:125 · 'AP' has no definition. Spell it out if it's unfamiliar to the audience.
Strong
warning

"It is important to remember that the dose length product is not the patient's effective dose. The effective dose depends on other factors including patient size and the region of the body being scanned. One of the method is Monte Carlo method that collect data from large number of X-rays to calculate the probability of photoelectric absorption or Compton effect in the phantom, assuming that the patient's interaction with X-rays is similar to the phantom (it is based and developed in fact, on two theorems: the law of large numbers and the central limit theorem) 6,7. The results are used to calculate absorbed doses. The absorbed doses are then multipled by organ dose coefficients to get the effective dose 5."

Line 5:235 · Generally, don't use bold in text: '<strong>Monte Carlo method</strong>'
Accepted Abbreviations
warning

"It is important to remember that the dose length product is not the patient's effective dose. The effective dose depends on other factors including patient size and the region of the body being scanned. One of the method is Monte Carlo method that collect data from large number of X-rays to calculate the probability of photoelectric absorption or Compton effect in the phantom, assuming that the patient's interaction with X-rays is similar to the phantom (it is based and developed in fact, on two theorems: the law of large numbers and the central limit theorem) 6,7. The results are used to calculate absorbed doses. The absorbed doses are then multipled by organ dose coefficients to get the effective dose 5."

Line 5:310 · Check the abbreviation form against the style guide: 'X-ray'.

"It is important to remember that the dose length product is not the patient's effective dose. The effective dose depends on other factors including patient size and the region of the body being scanned. One of the method is Monte Carlo method that collect data from large number of X-rays to calculate the probability of photoelectric absorption or Compton effect in the phantom, assuming that the patient's interaction with X-rays is similar to the phantom (it is based and developed in fact, on two theorems: the law of large numbers and the central limit theorem) 6,7. The results are used to calculate absorbed doses. The absorbed doses are then multipled by organ dose coefficients to get the effective dose 5."

Line 5:453 · Check the abbreviation form against the style guide: 'X-ray'.
Parentheses
suggestion

"Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:"

Line 1:32 · Use parentheses judiciously. There are at least 3 sets in this paragraph.