Login
Toggle sidebar

Lint: fast-spin-echo

Spacing
error

"In a basic SE sequence, a single echo is measured during each repetition time (TR). FSE is more efficient because multiple echoes are recorded after each 90-degree excitation pulse (multiple echoes per TR). This is achieved by transmitting a series of 180-degree inversion pulses at set intervals and measuring the corresponding echo according to a slightly different phase encoding gradient. In this way, multiple lines of K space (corresponding to multiple phase-encoded steps) are encoded after a single 90-degree pulse."

Line 3:401 · 't. I' should have one space.
Acronyms
warning

"Fast or turbo spin echo (FSE/TSE) is an adaptation of conventional spin-echo (SE) acquisition technique designed to reduce imaging time. It has largely supplanted the original spin-echo technique due to vastly improved imaging speed."

Line 1:71 · 'FSE' has no definition. Spell it out if it's unfamiliar to the audience.

"Fast or turbo spin echo (FSE/TSE) is an adaptation of conventional spin-echo (SE) acquisition technique designed to reduce imaging time. It has largely supplanted the original spin-echo technique due to vastly improved imaging speed."

Line 1:92 · 'TSE' has no definition. Spell it out if it's unfamiliar to the audience.

"In a basic SE sequence, a single echo is measured during each repetition time (TR). FSE is more efficient because multiple echoes are recorded after each 90-degree excitation pulse (multiple echoes per TR). This is achieved by transmitting a series of 180-degree inversion pulses at set intervals and measuring the corresponding echo according to a slightly different phase encoding gradient. In this way, multiple lines of K space (corresponding to multiple phase-encoded steps) are encoded after a single 90-degree pulse."

Line 3:86 · 'TR' has no definition. Spell it out if it's unfamiliar to the audience.

"In a basic SE sequence, a single echo is measured during each repetition time (TR). FSE is more efficient because multiple echoes are recorded after each 90-degree excitation pulse (multiple echoes per TR). This is achieved by transmitting a series of 180-degree inversion pulses at set intervals and measuring the corresponding echo according to a slightly different phase encoding gradient. In this way, multiple lines of K space (corresponding to multiple phase-encoded steps) are encoded after a single 90-degree pulse."

Line 3:95 · 'FSE' has no definition. Spell it out if it's unfamiliar to the audience.

"In a basic SE sequence, a single echo is measured during each repetition time (TR). FSE is more efficient because multiple echoes are recorded after each 90-degree excitation pulse (multiple echoes per TR). This is achieved by transmitting a series of 180-degree inversion pulses at set intervals and measuring the corresponding echo according to a slightly different phase encoding gradient. In this way, multiple lines of K space (corresponding to multiple phase-encoded steps) are encoded after a single 90-degree pulse."

Line 3:213 · 'TR' has no definition. Spell it out if it's unfamiliar to the audience.

"FSE results in reduced imaging times, with the extent of reduction dependent on the number of echoes produced in each cycle; this is also known as the echo train length. The improvement in imaging time is most powerful when used with a rectangular field of view (e.g. spinal imaging), and the phase encoding direction is chosen to correspond with the smallest matrix size dimension. This minimises the number of excitation pulse repetitions required per image."

Line 5:4 · 'FSE' has no definition. Spell it out if it's unfamiliar to the audience.

"Because echoes are generated using 180-degree inversion pulses, FSE retains the benefit of correcting for external magnetic field inhomogeneity. However, the benefit of reduced imaging time comes at a few costs:"

Line 6:68 · 'FSE' has no definition. Spell it out if it's unfamiliar to the audience.

"reduced signal to noise (SNR)echo amplitude decreases as a function of time from excitation pulse. Thus, later echoes will be subject to lower SNR"

Line 8:33 · 'SNR' has no definition. Spell it out if it's unfamiliar to the audience.

"reduced signal to noise (SNR)echo amplitude decreases as a function of time from excitation pulse. Thus, later echoes will be subject to lower SNR"

Line 8:163 · 'SNR' has no definition. Spell it out if it's unfamiliar to the audience.

"since multiple echoes are acquired per excitation pulse, FSE technique results in varying, progressively increased TE times during each TR acquisition cycle. This is more pronounced with longer echo train lengths"

Line 13:62 · 'FSE' has no definition. Spell it out if it's unfamiliar to the audience.

"since multiple echoes are acquired per excitation pulse, FSE technique results in varying, progressively increased TE times during each TR acquisition cycle. This is more pronounced with longer echo train lengths"

Line 13:141 · 'TR' has no definition. Spell it out if it's unfamiliar to the audience.

"the apparent or "effective" TE of the image depends on how the FSE-generated echoes are used to fill K space. A common technique involves filling the centre of K space, which contributes the most to image contrast, using the echoes that have desirable TE"

Line 14:68 · 'FSE' has no definition. Spell it out if it's unfamiliar to the audience.

"TSE technique also reduces the number of interleaved slices that can be obtained"

Line 17:5 · 'TSE' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Basic spin echo sequence"

Line 2:1 · "Basic spin echo sequence" is not a recognised heading for this article type.

"Fast spin echo sequence"

Line 4:1 · "Fast spin echo sequence" is not a recognised heading for this article type.
Semicolons
suggestion

"FSE results in reduced imaging times, with the extent of reduction dependent on the number of echoes produced in each cycle; this is also known as the echo train length. The improvement in imaging time is most powerful when used with a rectangular field of view (e.g. spinal imaging), and the phase encoding direction is chosen to correspond with the smallest matrix size dimension. This minimises the number of excitation pulse repetitions required per image."

Line 5:127 · Use semicolons judiciously.