Login
Toggle sidebar

Lint: liver-elastography-1

List Punctuation
error

"in 2D SWE, at least 5 measurements should be taken and represented as median (M), interquartile range (IQR)/ Median (M) along with stability index (SI); stability index should be >90% for good aquisition."

Line 37:201 · Do not put full stops at the end of a list item.
Adjectival Hyphens
error

"post-prandial status"

Line 59:8 · Only use medical adjectival hyphens where the letters at the end and start of the compound word are the same, e.g. post-transplant. In this case, don't use the hyphen: 'post-prandial'.
Acronyms
warning

"ROI taken 1.5-2.0 cm below liver capsule (to avoid reverberation artifacts of the liver capsule), not deeper than 6-7 cm with 4-4.5 cm considered optimum"

Line 34:4 · 'ROI' has no definition. Spell it out if it's unfamiliar to the audience.

"For viral aetiologies and NAFLD, the Society of Radiologists in Ultrasound proposes the following thresholds for ARFI techniques 3:"

Line 44:33 · 'NAFLD' has no definition. Spell it out if it's unfamiliar to the audience.

"AST/ALT values >5x of normal"

Line 56:8 · 'AST' has no definition. Spell it out if it's unfamiliar to the audience.

"AST/ALT values >5x of normal"

Line 56:12 · 'ALT' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Clinical applications
  • H2 Indications
  • H2 Contraindications
  • H1 Technique
  • H2 Physical principles
  • H2 Device structure
  • H2 Device function
  • H2 Image acquisition
  • H2 Image reconstruction
  • H2 Post-processing
  • H2 Technical advances
  • H2 Protocols
  • H1 Interpretation
  • H2 Normal values
  • H2 Limitations
  • H2 Pitfalls and artifacts
  • H1 History and etymology
  • H1 Practical points
  • H1 Related articles
  • H1 See also

"Imaging acquisition"

Line 27:1 · "Imaging acquisition" is not a recognised heading for this article type.
Oxford Comma
suggestion

"Liver elastography is a non-invasive imaging modality for identifying, quantifying and prognosing liver fibrosis. It can be done by ultrasound or MRI."

Line 1:79 · Use the Oxford comma in 'identifying, quantifying and prognosing'.
Semicolons
suggestion

"in point SWE, at least 5 measurements should be taken and represented as median (M), interquartile range (IQR)/ Median (M); if the IQR/M is not within range, 10 values should be taken"

Line 36:130 · Use semicolons judiciously.

"in 2D SWE, at least 5 measurements should be taken and represented as median (M), interquartile range (IQR)/ Median (M) along with stability index (SI); stability index should be >90% for good aquisition."

Line 37:159 · Use semicolons judiciously.
Parentheses
suggestion

"in 2D SWE, at least 5 measurements should be taken and represented as median (M), interquartile range (IQR)/ Median (M) along with stability index (SI); stability index should be >90% for good aquisition."

Line 37:85 · Use parentheses judiciously. There are at least 3 sets in this paragraph.