Login
Toggle sidebar

Lint: neonate-chest-supine-view

List Punctuation
error

"when performing this examination mobile in a special care nursery or ward, the scattered radiation to nearby neonatal patients and their family must be considered. It is essential to ensure that nearby neonates and family members are invited to leave the room or moved as far away as possible from the x-ray source during exposure 3."

Line 13:341 · Do not put full stops at the end of a list item.
Adjectival Hyphens
error

"entire lung fields should be visible; post-processing collimation is not advisable in paediatric imaging (if it is exposed it should be examined), if this is to be conducted, consider sending the non-digitally collimated image and resending it post collimated"

Line 51:43 · Only use medical adjectival hyphens where the letters at the end and start of the compound word are the same, e.g. post-transplant. In this case, don't use the hyphen: 'post-processing'.
Heading Citation
error

"Rotation 6"

Line 56:1 · Do not put citations in headings.
Litotes
warning

"Indications for a chest x-ray are far and wide from suspected infection to a pneumothorax. The specific reason why these radiographs are conducted supine is the fact neonates will often stay on the ward (performed mobile) and do not have reliable head control until around 3 months old 13."

Line 4:233 · Consider using 'lack(s)' instead of 'not have'
Strong
warning

"centring pointthe level of the 7th thoracic vertebra"

Line 20:1 · Generally, don't use bold in text: '<strong>centring point</strong>'

"collimation 4"

Line 24:1 · Generally, don't use bold in text: '<strong>collimation </strong>'

"orientation portrait"

Line 31:1 · Generally, don't use bold in text: '<strong>orientation</strong>'

"detector sizeoften smaller 'mini' detectors are used for the neonate chest x-ray"

Line 34:1 · Generally, don't use bold in text: '<strong>detector size</strong>'

"exposure 5"

Line 37:1 · Generally, don't use bold in text: '<strong>exposure </strong>'

"SID110 cm"

Line 43:1 · Generally, don't use bold in text: '<strong>SID</strong>'

"gridno"

Line 46:1 · Generally, don't use bold in text: '<strong>grid</strong>'
Acronyms
warning

"SID110 cm"

Line 43:9 · 'SID' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Indications
  • H1 Patient position
  • H1 Technical factors
  • H1 Image technical evaluation
  • H1 Practical points
  • H1 See also

"Rotation 6"

Line 56:1 · "Rotation <sup>6</sup> " is not a recognised heading for this article type.

"Lead shielding"

Line 62:1 · "Lead shielding" is not a recognised heading for this article type.

"Consent"

Line 67:1 · "Consent" is not a recognised heading for this article type.
Semicolons
suggestion

"entire lung fields should be visible; post-processing collimation is not advisable in paediatric imaging (if it is exposed it should be examined), if this is to be conducted, consider sending the non-digitally collimated image and resending it post collimated"

Line 51:41 · Use semicolons judiciously.

"The neonatal chest is technically demanding not due to the examination; the neonatal patient is often underweight, and unable to keep still."

Line 65:74 · Use semicolons judiciously.

"One of the most common repeated images in paediatric imaging is movement 7. To prevent movement during the examination will often require a staff member, in lead protection, to stay in the room holding the patient (often at the arms and legs). If this is the case, careful instruction should be provided to that staff member regarding the goal of the examination. Research regarding the most effective method of neonatal immobilisation is lacking; departmental protocols will vary."

Line 66:461 · Use semicolons judiciously.