Login
Toggle sidebar

Lint: pitch-ct

Headings Spacing
error

"Multislice CT (MSCT) "

Line 12:1 · Never put spaces at either end of headings.
Strong
warning

"The term detector pitch is the table distance travelled in one 360° gantry rotation divided by the beam collimation 2."

Line 3:13 · Generally, don't use bold in text: '<strong>detector pitch</strong>'

"Beam pitch is defined as table distance travelled in one 360° gantry rotation divided by the total thickness of all simultaneously acquired slices ref."

Line 13:4 · Generally, don't use bold in text: '<strong>Beam pitch</strong>'
List Caps
warning

"P = 1.0: x-ray beams are contiguous for adjacent rotations"

Line 7:8 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.

"P >1.0: x-ray beams are not contiguous for adjacent rotations; i.e. there are gaps in the x-ray helix, but the full volume is still irradiated, only with fewer projections per rotation"

Line 8:8 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.

"P"

Line 9:8 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Single slice CT (SSCT)"

Line 2:1 · "Single slice CT (SSCT)" is not a recognised heading for this article type.

"Multislice CT (MSCT) "

Line 12:1 · "Multislice CT (MSCT) " is not a recognised heading for this article type.
Semicolons
suggestion

"P >1.0: x-ray beams are not contiguous for adjacent rotations; i.e. there are gaps in the x-ray helix, but the full volume is still irradiated, only with fewer projections per rotation"

Line 8:69 · Use semicolons judiciously.

"P"

Line 9:43 · Use semicolons judiciously.