Login
Toggle sidebar

Lint: spatial-resolution-mri-2

Acronyms
warning

"The matrix size is the number of frequency encoding steps, in one direction; and the number of phase encoding steps, in the other direction of the image plane. Assuming everything else is constant, increasing the number of frequency encodings or the number of phase steps results in improved resolution. The frequency encoding depends on how rapidly the FID signal is sampled by the scanner. Increasing the sampling rate results in no time penalty. Increasing the number of phase steps increases the time of the acquisition proportionately. This is why images that have fewer phase encodings than frequency encodings, e.g. 128x256 or 192x256 will be used."

Line 3:358 · 'FID' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Matrix size"

Line 2:1 · "Matrix size" is not a recognised heading for this article type.

"Field of view"

Line 4:1 · "Field of view" is not a recognised heading for this article type.

"Slice thickness"

Line 6:1 · "Slice thickness" is not a recognised heading for this article type.
Semicolons
suggestion

"The matrix size is the number of frequency encoding steps, in one direction; and the number of phase encoding steps, in the other direction of the image plane. Assuming everything else is constant, increasing the number of frequency encodings or the number of phase steps results in improved resolution. The frequency encoding depends on how rapidly the FID signal is sampled by the scanner. Increasing the sampling rate results in no time penalty. Increasing the number of phase steps increases the time of the acquisition proportionately. This is why images that have fewer phase encodings than frequency encodings, e.g. 128x256 or 192x256 will be used."

Line 3:79 · Use semicolons judiciously.

"The field of view is the size of the area that the matrix of phase and frequency encoding cover. Dividing the field of view by the matrix size gives you the in-plane voxel size; hence, increasing the field of view in either direction increases the size of the voxels and decreases the resolution. Decreasing the field of view improves the resolution."

Line 5:180 · Use semicolons judiciously.
Links