Login
Toggle sidebar

Lint: ct-guided-adrenal-biopsy

Spacing
error

"Review the diagnostic CT and other relevant imaging first (e.g. MRI and PET-CT) to clarify the lesion that is requested to be biopsied. Ensure that previously dedicated adrenal CT and chemical shift MRI protocols were performed to evaluate adrenal masses for characteristics specific to adrenal adenomas 3."

Line 32:137 · 'd. E' should have one space.
Adjectival Hyphens
error

"Post-procedure care"

Line 43:5 · Only use medical adjectival hyphens where the letters at the end and start of the compound word are the same, e.g. post-transplant. In this case, don't use the hyphen: 'Post-procedure'.
Acronyms
warning

"Ultrasound is also an option for guidance but is less used nowadays. The choice of CT or US guidance was made by the radiologist."

Line 2:93 · 'US' has no definition. Spell it out if it's unfamiliar to the audience.

"Bed rest is advised as well as regular observations for four hours (pulse, BP, SpO2). The observation period should allow an ample opportunity to identify and treat any potential complications promptly to prevent a severe or catastrophic outcome; it varies per each institution protocol."

Line 44:79 · 'BP' has no definition. Spell it out if it's unfamiliar to the audience.
Numbers Over10000
warning

"platelets >50000/mm3 (some institutions use other values between 50000-100000/mm3) 2"

Line 20:23 · Use a thousands separators for large numbers.

"platelets >50000/mm3 (some institutions use other values between 50000-100000/mm3) 2"

Line 20:89 · Use a thousands separators for large numbers.

"platelets >50000/mm3 (some institutions use other values between 50000-100000/mm3) 2"

Line 20:95 · Use a thousands separators for large numbers.
Ranges
warning

"platelets >50000/mm3 (some institutions use other values between 50000-100000/mm3) 2"

Line 20:81 · Don't add words such as 'from' or 'between' to describe a range of numbers.
Headings Valid
warning

Expected headings

  • H1 Indications
  • H1 Contraindications
  • H1 Preprocedural evaluation
  • H1 Procedure
  • H2 Equipment
  • H2 Technique
  • H2 Postprocedural care
  • H1 Postprocedural evaluation
  • H2 Radiographic features
  • H1 Complications
  • H1 Outcomes
  • H1 History and etymology
  • H1 See also

"Laboratory parameters for a safe procedure"

Line 15:1 · "Laboratory parameters for a safe procedure" is not a recognised heading for this article type.

"Preprocedure evaluation"

Line 31:1 · "Preprocedure evaluation" is not a recognised heading for this article type.

"Positioning"

Line 33:1 · "Positioning" is not a recognised heading for this article type.

"Biopsy"

Line 35:1 · "Biopsy" is not a recognised heading for this article type.

"Post-procedure care"

Line 43:1 · "Post-procedure care" is not a recognised heading for this article type.
There Is
suggestion

"There are widely divergent opinions about the safe values of these indices for percutaneous biopsies. The values suggested below were considered based on the literature review, whose references are cited below:"

Line 16:4 · Don't start a sentence with 'There are'.
Semicolons
suggestion

"Bed rest is advised as well as regular observations for four hours (pulse, BP, SpO2). The observation period should allow an ample opportunity to identify and treat any potential complications promptly to prevent a severe or catastrophic outcome; it varies per each institution protocol."

Line 44:249 · Use semicolons judiciously.