Login
Toggle sidebar

Lint: ionisation-chamber

List Punctuation
error

"ionisation chambers are dosimetry devices used to measure the output of x-ray tubes. They function as photo timers in automatic exposure controls and in nuclear medicine, as dose calibrators."

Line 5:204 · Do not put full stops at the end of a list item.

"pocket ionisation chambers are a portable form of dosimetry devices in the shape of large pens. They provide immediate readings, are easily recharged and reused but are not very accurate due to their mechanical fragility."

Line 7:229 · Do not put full stops at the end of a list item.

"Geiger counters have a high voltage across the chamber. Due to the high voltage and positive potential, liberated electrons are accelerated and gain energy, resulting in more liberated electrons from the chamber and amplification of liberated charge (electron avalanche). Therefore, they are highly sensitive and are used to detect radioactive contamination (low level of radiation)."

Line 9:390 · Do not put full stops at the end of a list item.
Acronyms
warning

"Ionisation chambers measure exposure by detecting liberated electron charge when x-ray photons ionise the gas within the chamber. The chambers need a high positive voltage applied at the collecting anode to attract the liberated electrons. The electron charge is collected and used to determine the radiographic exposure expressed in coulombs per kilogram (C/kg), the preferred SI unit, or the legacy unit, roentgens (R)."

Line 1:430 · 'SI' has no definition. Spell it out if it's unfamiliar to the audience.
Strong
warning

"ionisation chambers are dosimetry devices used to measure the output of x-ray tubes. They function as photo timers in automatic exposure controls and in nuclear medicine, as dose calibrators."

Line 5:1 · Generally, don't use bold in text: '<strong>ionisation chambers</strong>'

"pocket ionisation chambers are a portable form of dosimetry devices in the shape of large pens. They provide immediate readings, are easily recharged and reused but are not very accurate due to their mechanical fragility."

Line 7:1 · Generally, don't use bold in text: '<strong>pocket ionisation chambers</strong>'

"Geiger counters have a high voltage across the chamber. Due to the high voltage and positive potential, liberated electrons are accelerated and gain energy, resulting in more liberated electrons from the chamber and amplification of liberated charge (electron avalanche). Therefore, they are highly sensitive and are used to detect radioactive contamination (low level of radiation)."

Line 9:1 · Generally, don't use bold in text: '<strong>Geiger counters</strong>'
List Caps
warning

"Geiger counters have a high voltage across the chamber. Due to the high voltage and positive potential, liberated electrons are accelerated and gain energy, resulting in more liberated electrons from the chamber and amplification of liberated charge (electron avalanche). Therefore, they are highly sensitive and are used to detect radioactive contamination (low level of radiation)."

Line 9:9 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.
There Is
suggestion

"There are different types of ionisation chambers:"

Line 2:4 · Don't start a sentence with 'There are'.