Login
Toggle sidebar

Lint: ultrasound-guided-breast-biopsy

List Punctuation
error

"study the target lesion and its best biopsy approach."

Line 21:52 · Do not put full stops at the end of a list item.

"skin antisepsis."

Line 22:13 · Do not put full stops at the end of a list item.

"local block with 1% lidocaine using US guidance while injecting it."

Line 23:72 · Do not put full stops at the end of a list item.

"a small incision is made with a scalpel blade or a large bore hypodermic needle (enough to overcome resistance and allow the entry of the core-needle biopsy)."

Line 24:158 · Do not put full stops at the end of a list item.

"ultrasound-guided introduction of the core-needle biopsy and subsequent removal of the fragments."

Line 25:95 · Do not put full stops at the end of a list item.

"local compression may be necessary to stop any bleeding."

Line 26:55 · Do not put full stops at the end of a list item.

"skin cleansing and dressing."

Line 27:27 · Do not put full stops at the end of a list item.
Adjectival Hyphens
error

"post-biopsy obscuration of the target lesion, particularly if very small or had a ruptured cystic component; consider placement or marker/clip in such cases"

Line 36:8 · Only use medical adjectival hyphens where the letters at the end and start of the compound word are the same, e.g. post-transplant. In this case, don't use the hyphen: 'post-biopsy'.
Acronyms
warning

"Ultrasound guidance is limited to lesions visible on ultrasound study. The biopsy is generally undertaken for lesions that are assessed as BI-RADS 4 (suspicious for malignancy) or BI-RADS 5 (highly suggestive of malignancy)."

Line 3:146 · 'BI-RADS' has no definition. Spell it out if it's unfamiliar to the audience.

"Ultrasound guidance is limited to lesions visible on ultrasound study. The biopsy is generally undertaken for lesions that are assessed as BI-RADS 4 (suspicious for malignancy) or BI-RADS 5 (highly suggestive of malignancy)."

Line 3:194 · 'BI-RADS' has no definition. Spell it out if it's unfamiliar to the audience.

"local block with 1% lidocaine using US guidance while injecting it."

Line 23:44 · 'US' has no definition. Spell it out if it's unfamiliar to the audience.
Number Formatting
warning

"chlorhexidine, surgical scalpel blade (usually n.11), needle and syringe for anaesthetic, dressing, and sterile gloves"

Line 17:56 · Check the number format against the style guide: '.11'.
Headings Valid
warning

Expected headings

  • H1 Indications
  • H1 Contraindications
  • H1 Preprocedural evaluation
  • H1 Procedure
  • H2 Equipment
  • H2 Technique
  • H2 Postprocedural care
  • H1 Postprocedural evaluation
  • H2 Radiographic features
  • H1 Complications
  • H1 Outcomes
  • H1 History and etymology
  • H1 See also

"Preprocedural evaluation"

Line 7:1 · "Preprocedural evaluation" should be H1, not H2.

"Positioning"

Line 9:1 · "Positioning" is not a recognised heading for this article type.
Oxford Comma
suggestion

"Ultrasound-guided percutaneous breast biopsy is a widely used technique for an accurate histopathological assessment of suspected breast pathology. It is a fast, safe and economical procedure."

Line 1:177 · Use the Oxford comma in 'fast, safe and economical'.

"14G or 16G core biopsy needle, single or co-axial, with 10 mm or 20 mm cutting lengths"

Line 14:31 · Use the Oxford comma in 'needle, single or co'.
Semicolons
suggestion

"post-biopsy obscuration of the target lesion, particularly if very small or had a ruptured cystic component; consider placement or marker/clip in such cases"

Line 36:115 · Use semicolons judiciously.