Login
Toggle sidebar

Lint: 15-t-vs-30-t-2

Acronyms
warning

"The specific absorption rate (SAR) is defined as the amount of radiofrequency energy (joules) deposited in tissues (kg). The limit set by the FDA is an amount that results in an increase of 1-degree centigrade in any tissue 2. SAR is proportional to the static field (B0) squared, meaning that a 3 T system deposits four times as much energy within tissue as a 1.5 T system. Additionally, SAR is proportional to"

Line 14:146 · 'FDA' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Signal-to-noise ratio"

Line 11:1 · "Signal-to-noise ratio" is not a recognised heading for this article type.

"Specific absorption rate"

Line 13:1 · "Specific absorption rate" is not a recognised heading for this article type.

"Acoustic noise"

Line 22:1 · "Acoustic noise" is not a recognised heading for this article type.
Semicolons
suggestion

"Comparing 1.5 T vs 3.0 T (1.5 tesla vs 3.0 tesla) MRI systems identifies several differences; a 3 T system has"

Line 1:128 · Use semicolons judiciously.

"It is important to emphasise that in common with standard scientific unit notation, a space must always be inserted between the quantity and the unit symbol; therefore, 1.5 T and 3 T are correct. Conversely, 1.5T and 3T are incorrect, despite the latter usages often being seen in medical media and some radiology reports."

Line 10:167 · Use semicolons judiciously.
Parentheses
suggestion

"The specific absorption rate (SAR) is defined as the amount of radiofrequency energy (joules) deposited in tissues (kg). The limit set by the FDA is an amount that results in an increase of 1-degree centigrade in any tissue 2. SAR is proportional to the static field (B0) squared, meaning that a 3 T system deposits four times as much energy within tissue as a 1.5 T system. Additionally, SAR is proportional to"

Line 14:33 · Use parentheses judiciously. There are at least 3 sets in this paragraph.