Login
Toggle sidebar

Lint: ct-pancreas-protocol-1

Units
error

"staging and severity assessment (best-done ≥2-3days after symptom onset)"

Line 29:54 · Put a space between the number and the unit in '3d'.

"neutral contrast agent: 800 ml water 20-30min before the scan"

Line 80:49 · Put a space between the number and the unit in '20-30min'.

"contrast volume: 70-120ml (1 mL/kg) with 30-40 mL saline chaser at 3-5 mL/s"

Line 89:25 · Put a space between the number and the unit in '70-120ml'.

"contrast volume: 70-120ml (1 mL/kg) with 30-40 mL saline chaser at 4-5 mL/s"

Line 98:25 · Put a space between the number and the unit in '70-120ml'.

"contrast volume: 70-120ml (1 mL/kg) with 30-40 mL saline chaser at 3-5 mL/s"

Line 107:25 · Put a space between the number and the unit in '70-120ml'.
Emphasis
warning

"Note: This article aims to frame a general concept of a CT protocol for the assessment of the pancreas. Protocol specifics will vary depending on CT scanner type, specific hardware and software, radiologist and perhaps referrer preference, patient factors e.g. implants, specific indications."

Line 2:4 · Italics should be used only in exceptional circumstances: '<em>Note: This article aims to frame a general concept of a CT protocol for the assessment of the pancreas. Protocol specifics will vary depending on CT scanner type, specific hardware and software, radiologist and perhaps referrer preference, patient factors e.g. implants, specific indications.</em>'
Colons
warning

"Note: This article aims to frame a general concept of a CT protocol for the assessment of the pancreas. Protocol specifics will vary depending on CT scanner type, specific hardware and software, radiologist and perhaps referrer preference, patient factors e.g. implants, specific indications."

Line 2:12 · The first word after a colon should almost always be lowercase. In this case, it's not: ': This article'.
Acronyms
warning

"field of view (FOV): 350 mm (should be adjusted to increase in-plane resolution)"

Line 73:23 · 'FOV' has no definition. Spell it out if it's unfamiliar to the audience.
Unit Capitalisation
warning

"neutral contrast agent: 800 ml water 20-30min before the scan"

Line 80:36 · Unit names are lowercase in full, and the litre takes a capital L: '800 ml'.

"contrast volume: 70-120ml (1 mL/kg) with 30-40 mL saline chaser at 3-5 mL/s"

Line 89:28 · Unit names are lowercase in full, and the litre takes a capital L: '120ml'.

"contrast volume: 70-120ml (1 mL/kg) with 30-40 mL saline chaser at 4-5 mL/s"

Line 98:28 · Unit names are lowercase in full, and the litre takes a capital L: '120ml'.

"contrast volume: 70-120ml (1 mL/kg) with 30-40 mL saline chaser at 3-5 mL/s"

Line 107:28 · Unit names are lowercase in full, and the litre takes a capital L: '120ml'.
Strong
warning

"axial images: strictly axial to the body axis"

Line 120:8 · Generally, don't use bold in text: 'axial images:<strong> </strong>strictly axial to the body axis'
Headings Valid
warning

Expected headings

  • H1 Indications
  • H1 Contraindications
  • H1 Technique
  • H2 Patient position
  • H2 Scout
  • H2 Scan extent
  • H2 Scan direction
  • H2 Scan duration
  • H2 Contrast
  • H2 Scan delay
  • H1 Practical points
  • H1 Post-processing
  • H1 Related articles
  • H1 See also

"Purpose"

Line 14:1 · "Purpose" is not a recognised heading for this article type.
Oxford Comma
suggestion

"Note: This article aims to frame a general concept of a CT protocol for the assessment of the pancreas. Protocol specifics will vary depending on CT scanner type, specific hardware and software, radiologist and perhaps referrer preference, patient factors e.g. implants, specific indications."

Line 2:193 · Use the Oxford comma in 'software, radiologist and perhaps'.
Inline EG
suggestion

"pancreatic interventions (e.g. CT-guided biopsy, drainage)"

Line 12:33 · Consider replacing a bracketed e.g. with an inline e.g. after a comma.