Lint: electronic-personal-dosimeter-1

Uncomparables
error

"Most whole-body EPDs measure only Hp(10). Dose is typically displayed in sieverts (Sv) and dose rate in microsieverts or millisieverts per hour (µSv/h or mSv/h) 4."

Line 18:4 · 'Most whole' is not comparable
List Caps
warning

"Hp(10): personal dose equivalent at a depth of 10 mm; used for more penetrating radiation (e.g. x-rays, gamma rays); does not directly measure effective dose 4"

Line 14:8 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.

"Hp(0.07): dose at a depth of 0.07 mm; used to assess superficial exposure to skin and extremities 2,3"

Line 15:8 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.

"Hp(3): dose at a depth of 3 mm; used specifically to assess dose to the lens of the eye"

Line 16:8 · In general, we don't start a list item with a capital letter. Exceptions are proper nouns.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Physical principles"

Line 2:1 · "Physical principles" is not a recognised heading for this article type.

"Device structure"

Line 19:1 · "Device structure" is not a recognised heading for this article type.

"Limitations"

Line 31:1 · "Limitations" is not a recognised heading for this article type.
Semicolons
suggestion

"the signal is amplified and energy compensation applied; because skin and silicon differ in density and therefore absorb radiation at different rates, as defined by the linear attenuation coefficient, filters or correction algorithms are used to bring the response closer to the true tissue dose 1,4"

Line 9:63 · Use semicolons judiciously.

"Hp(10): personal dose equivalent at a depth of 10 mm; used for more penetrating radiation (e.g. x-rays, gamma rays); does not directly measure effective dose 4"

Line 14:60 · Use semicolons judiciously.

"Hp(10): personal dose equivalent at a depth of 10 mm; used for more penetrating radiation (e.g. x-rays, gamma rays); does not directly measure effective dose 4"

Line 14:123 · Use semicolons judiciously.

"Hp(0.07): dose at a depth of 0.07 mm; used to assess superficial exposure to skin and extremities 2,3"

Line 15:44 · Use semicolons judiciously.

"Hp(3): dose at a depth of 3 mm; used specifically to assess dose to the lens of the eye"

Line 16:38 · Use semicolons judiciously.
Oxford Comma
suggestion

"the signal is amplified and energy compensation applied; because skin and silicon differ in density and therefore absorb radiation at different rates, as defined by the linear attenuation coefficient, filters or correction algorithms are used to bring the response closer to the true tissue dose 1,4"

Line 9:199 · Use the Oxford comma in 'coefficient, filters or correction'.