Lint: milliampere-seconds-mas

Headings Spacing
error

"The reciprocity law "

Line 6:1 · Never put spaces at either end of headings.
Strong
warning

"mA x t = mAs (strictly mA.s but the "." is always omitted)600 mA x 0.1 s = 60 mAs"

Line 4:4 · Generally, don't use bold in text: '<strong>mA x t = mAs </strong>'

"mA x t = mAs (strictly mA.s but the "." is always omitted)600 mA x 0.1 s = 60 mAs"

Line 4:79 · Generally, don't use bold in text: '<strong>600 mA x 0.1 s = 60 mAs</strong>'

"50 mA x 0.2 se = 10 mAs is equal to 300 mA x 0.03 s = 10 mAs"

Line 8:4 · Generally, don't use bold in text: '<strong>50 mA x 0.2 se = 10 mAs</strong>'

"50 mA x 0.2 se = 10 mAs is equal to 300 mA x 0.03 s = 10 mAs"

Line 8:57 · Generally, don't use bold in text: '<strong>300 mA x 0.03 s = 10 mAs</strong>'
Acronyms
warning

"It is due to this law that radiographers will have to take into consideration all other factors (mA, focal spot, source image receptor distance (SID), kVp) to reduce time to avoid motion blur."

Line 9:166 · 'SID' has no definition. Spell it out if it's unfamiliar to the audience.
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"The reciprocity law "

Line 6:1 · "The reciprocity law " is not a recognised heading for this article type.
Semicolons
suggestion

"An increase in tube current (mA) results in a higher production of electrons that are inside the x-ray tube which will, therefore, increase the quantity of x-radiation; more radiation will mean more photons reaching the detector and hence apparent structural density will decrease, yet the signal intensity will increase. The time factor (s) is a measure of the electrons production duration in the tube; meaning 's' prescribes how long mA will last."

Line 2:185 · Use semicolons judiciously.

"An increase in tube current (mA) results in a higher production of electrons that are inside the x-ray tube which will, therefore, increase the quantity of x-radiation; more radiation will mean more photons reaching the detector and hence apparent structural density will decrease, yet the signal intensity will increase. The time factor (s) is a measure of the electrons production duration in the tube; meaning 's' prescribes how long mA will last."

Line 2:421 · Use semicolons judiciously.

"Increasing either the current or time will increase the quantity of radiation; therefore the amount of radiation in an examination is represented as mAs."

Line 5:81 · Use semicolons judiciously.