Login
Toggle sidebar

Lint: x-ray-tube-1

Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Usage
  • H1 Epidemiology
  • H2 Risk factors
  • H2 Associations
  • H1 Clinical presentation
  • H2 Complications
  • H1 Diagnosis
  • H2 Diagnostic criteria
  • H2 Diagnostic clues
  • H1 Pathology
  • H2 Aetiology
  • H2 Location
  • H2 Classification
  • H2 Macroscopic appearance
  • H2 Microscopic appearance
  • H2 Immunophenotype
  • H2 Markers
  • H2 Genetics
  • H1 Radiographic features
  • H2 Plain radiograph
  • H2 Mammography
  • H2 Antenatal ultrasound
  • H2 Transoesophageal echocardiography
  • H2 Ultrasound
  • H2 CT
  • H3 Dual-energy CT
  • H2 Angiography (DSA)
  • H2 MRI
  • H2 CT/MRI
  • H2 Nuclear medicine
  • H3 PET-CT
  • H3 PET-MRI
  • H1 Radiology report
  • H1 Treatment and prognosis
  • H2 Complications
  • H1 History and etymology
  • H1 Differential diagnosis
  • H2 Clinical differential diagnosis
  • H1 Practical points
  • H1 See also

"Construction"

Line 3:1 · "Construction" is not a recognised heading for this article type.

"Principal elements"

Line 4:1 · "Principal elements" is not a recognised heading for this article type.

"Additional elements"

Line 9:1 · "Additional elements" is not a recognised heading for this article type.

"Other parts of an x-ray system"

Line 16:1 · "Other parts of an x-ray system" is not a recognised heading for this article type.

"Function"

Line 18:1 · "Function" is not a recognised heading for this article type.

"Filament (cathode) and target (anode)"

Line 19:1 · "Filament (cathode) and target (anode)" is not a recognised heading for this article type.

"Anode rotor and induction stator"

Line 23:1 · "Anode rotor and induction stator" is not a recognised heading for this article type.

"Tube envelope"

Line 26:1 · "Tube envelope" is not a recognised heading for this article type.

"Tube window"

Line 28:1 · "Tube window" is not a recognised heading for this article type.

"Coolant"

Line 30:1 · "Coolant" is not a recognised heading for this article type.

"Tube housing"

Line 32:1 · "Tube housing" is not a recognised heading for this article type.

"Generator"

Line 34:1 · "Generator" is not a recognised heading for this article type.
Oxford Comma
suggestion

"The filament/cathode and target/anode are contained in the envelope, which provides vacuum, support and electrical insulation. The envelope is made of glass (Pyrex or borosilicate glass) 8, ceramic, or metal 4. A glass envelope is more prone to failure because tungsten filament vapourises and coats the surface of the glass, altering the electric potential of the tube, and resulting in the formation of an electric arc, causing tube failure. A metal envelope maintains the electric potential across the tube, making it less likely to fail. Thus, most high-output x-ray tubes use metal envelopes 6."

Line 27:88 · Use the Oxford comma in 'vacuum, support and electrical'.