"In case of contrast enhanced MRC, precontrast T1 (fat suppressed) and 3D T2 weighted images are obtained 1. 0.5 mL of gadopentetate dimeglumine (Gd-DTPA) is injected in the L4-L5 lumbar region using a 2426-gauge needle 1. Post-contrast images include early-phase imaging within 6 hours and late-phase imaging 1."

Line 33:218 · Use a hyphen-minus ('-') instead of an en-dash ('–').
Adjectival Hyphens
error

"In case of contrast enhanced MRC, precontrast T1 (fat suppressed) and 3D T2 weighted images are obtained 1. 0.5 mL of gadopentetate dimeglumine (Gd-DTPA) is injected in the L4-L5 lumbar region using a 24–26-gauge needle 1. Post-contrast images include early-phase imaging within 6 hours and late-phase imaging 1."

Line 33:249 · Only use medical adjectival hyphens where the letters at the end and start of the compound word are the same, e.g. post-transplant. In this case, don't use the hyphen: 'Post-contrast'.
Strong List Colon Position
error

"Off-label warning: The use of gadolinium-based contrast agents for intrathecal administration is not approved by regulatory agencies such as the FDA. Read more: intrathecal gadolinium"

Line 34:4 · When enboldening an intro, the colon should not be bold. '<strong>Off-label warning:</strong> The'
Headings Spacing
error

"History and etymology "

Line 37:1 · Never put spaces at either end of headings.
Acronyms
warning

"3D PSIF - reversed fast imaging with steady state precession (FISP) 1,4"

Line 28:11 · 'PSIF' has no definition. Spell it out if it's unfamiliar to the audience.

"Off-label warning: The use of gadolinium-based contrast agents for intrathecal administration is not approved by regulatory agencies such as the FDA. Read more: intrathecal gadolinium"

Line 34:173 · 'FDA' has no definition. Spell it out if it's unfamiliar to the audience.
Spinal Level Format
warning

"In case of contrast enhanced MRC, precontrast T1 (fat suppressed) and 3D T2 weighted images are obtained 1. 0.5 mL of gadopentetate dimeglumine (Gd-DTPA) is injected in the L4-L5 lumbar region using a 24–26-gauge needle 1. Post-contrast images include early-phase imaging within 6 hours and late-phase imaging 1."

Line 33:188 · Consider removing the duplication of spinal level in the second reference 'L4-L5'.
Strong
warning

"Off-label warning: The use of gadolinium-based contrast agents for intrathecal administration is not approved by regulatory agencies such as the FDA. Read more: intrathecal gadolinium"

Line 34:4 · Generally, don't use bold in text: '<strong>Off-label warning:</strong>'
Headings Valid
warning

Expected headings

  • H1 Terminology
  • H1 Clinical applications
  • H2 Indications
  • H2 Contraindications
  • H1 Technique
  • H2 Physical principles
  • H2 Device structure
  • H2 Device function
  • H2 Image acquisition
  • H2 Image reconstruction
  • H2 Post-processing
  • H2 Technical advances
  • H2 Protocols
  • H1 Interpretation
  • H2 Normal values
  • H2 Limitations
  • H2 Pitfalls and artifacts
  • H1 History and etymology
  • H1 Practical points
  • H1 Related articles
  • H1 See also

"Non-contrast cisternography"

Line 25:1 · "Non-contrast cisternography" is not a recognised heading for this article type.

"Contrast cisternography"

Line 32:1 · "Contrast cisternography" is not a recognised heading for this article type.

"Limitations"

Line 35:1 · "Limitations" should be H2, not H1.

"History and etymology "

Line 37:1 · "History and etymology " is not a recognised heading for this article type.
MRI Vendor Sequences
suggestion

"3D PSIF - reversed fast imaging with steady state precession (FISP) 1,4"

Line 28:70 · 'FISP' is an MRI-manufacturer-specific sequence, try to avoid using these.

"3D T2 DRIVE sequence- driven equilibrium pulse sequence using TSE (turbo- spin echo) technique 3"

Line 30:14 · 'DRIVE' is an MRI-manufacturer-specific sequence, try to avoid using these.