Login
Toggle sidebar

Lint: epilepsy-protocol-mri

Units
error

"3D ≤1mm isotropic acquisition"

Line 14:12 · Put a space between the number and the unit in '1mm'.

"≤3mm (or 3D isotropic if available)"

Line 36:9 · Put a space between the number and the unit in '3mm'.

"≤1mm inplane resolution (as low as possible)"

Line 56:9 · Put a space between the number and the unit in '1mm'.

"≤3mm (or 3D isotropic if available)"

Line 76:9 · Put a space between the number and the unit in '3mm'.

"≤3mm (or 3D isotropic if available)"

Line 116:9 · Put a space between the number and the unit in '3mm'.
Acronyms
warning

"Generally, fewer high-quality sequences are preferable to more numerous lower-resolution sequences (e.g. HARNESS‐MRI protocol 7)."

Line 3:109 · 'HARNESS' has no definition. Spell it out if it's unfamiliar to the audience.

"planes: axial (AC-PC), sagittal and coronal"

Line 15:26 · 'AC-PC' has no definition. Spell it out if it's unfamiliar to the audience.

"planes: axial (AC-PC) and coronal"

Line 40:26 · 'AC-PC' has no definition. Spell it out if it's unfamiliar to the audience.

"planes: axial (AC-PC)"

Line 80:26 · 'AC-PC' has no definition. Spell it out if it's unfamiliar to the audience.

"planes: axial (AC-PC)"

Line 100:26 · 'AC-PC' has no definition. Spell it out if it's unfamiliar to the audience.

"planes: axial (AC-PC) and coronal"

Line 120:26 · 'AC-PC' has no definition. Spell it out if it's unfamiliar to the audience.
Emphasis
warning

"Note: This article is intended to outline some general principles of protocol design. The specifics will vary depending on MRI hardware and software, radiologist and referrer preference, institutional protocols, patient factors (e.g., allergy), and time constraints. "

Line 4:4 · Italics should be used only in exceptional circumstances: '<em>Note: This article is intended to outline some general principles of protocol design. The specifics will vary depending on MRI hardware and software, radiologist and referrer preference, institutional protocols, patient factors (e.g., allergy), and time constraints. </em>'
Colons
warning

"Note: This article is intended to outline some general principles of protocol design. The specifics will vary depending on MRI hardware and software, radiologist and referrer preference, institutional protocols, patient factors (e.g., allergy), and time constraints."

Line 4:12 · The first word after a colon should almost always be lowercase. In this case, it's not: ': This article'.
Accepted Abbreviations
warning

"look for cortical or subcortical hyperintensities (e.g. radial glial bands, infarcts, demyelination, abnormal cortex etc...)"

Line 44:132 · Check the abbreviation form against the style guide: 'etc..'.
Ellipses
warning

"look for cortical or subcortical hyperintensities (e.g. radial glial bands, infarcts, demyelination, abnormal cortex etc...)"

Line 44:135 · Don't use an ellipsis... in written text.
Headings Valid
warning

Expected headings

  • H1 Indications
  • H1 1.5 vs 3 tesla
  • H1 Patient preparation
  • H1 Patient positioning
  • H1 Technical parameters
  • H2 Coil
  • H2 Scan geometry
  • H2 Planning
  • H1 Sequences
  • H2 Standard sequences
  • H2 Optional sequences
  • H1 Practical points
  • H1 Related articles
  • H1 See also

"Additional sequences"

Line 108:1 · "Additional sequences" is not a recognised heading for this article type.
Inline EG
suggestion

"MRI protocol for epilepsy is a set of MRI sequences aimed at improving sensitivity and specificity in identifying possible structural abnormalities that underlie epilepsy (e.g. mesial temporal sclerosis and malformation of cortical development)."

Line 1:206 · Consider replacing a bracketed e.g. with an inline e.g. after a comma.

"Generally, fewer high-quality sequences are preferable to more numerous lower-resolution sequences (e.g. HARNESS‐MRI protocol 7)."

Line 3:103 · Consider replacing a bracketed e.g. with an inline e.g. after a comma.

"look for cortical or subcortical hyperintensities (e.g. radial glial bands, infarcts, demyelination, abnormal cortex etc...)"

Line 44:58 · Consider replacing a bracketed e.g. with an inline e.g. after a comma.

"identify focal lesions (e.g. tumours)"

Line 45:31 · Consider replacing a bracketed e.g. with an inline e.g. after a comma.

"The role of post-contrast T1 sequences is usually reserved for cases where enhancing lesions are suspected either on prior imaging or on the basis of history (e.g. prior maligancny)."

Line 124:162 · Consider replacing a bracketed e.g. with an inline e.g. after a comma.
Oxford Comma
suggestion

"Note: This article is intended to outline some general principles of protocol design. The specifics will vary depending on MRI hardware and software, radiologist and referrer preference, institutional protocols, patient factors (e.g., allergy), and time constraints."

Line 4:148 · Use the Oxford comma in 'software, radiologist and referrer'.

"visualise brain anatomy, morphology and volume"

Line 22:24 · Use the Oxford comma in 'anatomy, morphology and volume'.