"T2 mapping has been conducted with T2 turbo spin multi-echo (T2-TSE) 2,5, T2 prepared steady-state free precession (T2p-SSFP) 2,5,8,9, as well as T2 gradient spin echo mapping sequences (T2-GraSE) 10,11. No matter which acquisition technique is used a series of co-registered images is acquired with different T2 echo times 1-4,6-9."

Line 34:68 · 'TSE' has no definition. Spell it out if it's unfamiliar to the audience.

"T2 mapping has been conducted with T2 turbo spin multi-echo (T2-TSE) 2,5, T2 prepared steady-state free precession (T2p-SSFP) 2,5,8,9, as well as T2 gradient spin echo mapping sequences (T2-GraSE) 10,11. No matter which acquisition technique is used a series of co-registered images is acquired with different T2 echo times 1-4,6-9."

Line 34:142 · 'SSFP' has no definition. Spell it out if it's unfamiliar to the audience.

"Normal values of T2 times differ depending on magnetic field strength (1,5 and 3 Tesla), and acquisition sequence (T2-SSFP, GraSE). Because of variations between scanners, the primary use of a local reference range is recommended 1,4 and if a local reference range is not available quantitative results should not be clinically reported 1,4."

Line 40:122 · 'SSFP' has no definition. Spell it out if it's unfamiliar to the audience.
EG List And
warning

"T2 values can then be computed pixel-wise from a signal intensity versus echo time curve fitting model 1-3,12. The variation of other weight factors, e.g. T1 off-resonance, needs to be corrected if not negligibly small, and displacement between the images of the series should be avoided to get accurate values 1,12."

Line 35:172 · An e.g. list gives selected examples, so it should not end with 'and' or 'or': 'e.g. T1 off-resonance, needs to be corrected if not negligibly small, and'.
Unit Capitalisation
warning

"Normal values of T2 times differ depending on magnetic field strength (1,5 and 3 Tesla), and acquisition sequence (T2-SSFP, GraSE). Because of variations between scanners, the primary use of a local reference range is recommended 1,4 and if a local reference range is not available quantitative results should not be clinically reported 1,4."

Line 40:83 · Unit names are lowercase in full, and the litre takes a capital L: '3 Tesla'.
Commas
suggestion

"T2 mapping has been conducted with T2 turbo spin multi-echo (T2-TSE) 2,5, T2 prepared steady-state free precession (T2p-SSFP) 2,5,8,9, as well as T2 gradient spin echo mapping sequences (T2-GraSE) 10,11. No matter which acquisition technique is used a series of co-registered images is acquired with different T2 echo times 1-4,6-9."